課題データ / Project Data

課題番号 / Project Issue Number

24KU1050

利用課題名 / Title

In vivo function-persistent polymersome nanoreactor with tumor-specific activation and safe clearance/metabolism for synergistic oxidation-chemo-immunotherapy

利用した実施機関 / Support Institute

九州大学 / Kyushu Univ.

機関外・機関内の利用 / External or Internal Use

内部利用(ARIM事業参画者以外)/Internal Use (by non ARIM members)

技術領域 / Technology Area

【横断技術領域 / Cross-Technology Area】(主 / Main)物質・材料合成プロセス/Molecule & Material Synthesis(副 / Sub)-

【重要技術領域 / Important Technology Area】(主 / Main)次世代ナノスケールマテリアル/Next-generation nanoscale materials(副 / Sub)次世代バイオマテリアル/Next-generation biomaterials

キーワード / Keywords

DDSマテリアル/ DDS material, 質量分析/ Mass spectrometry


利用者と利用形態 / User and Support Type

利用者名(課題申請者)/ User Name (Project Applicant)

WEN Panyue

所属名 / Affiliation

九州大学 先導物質化学研究所

共同利用者氏名 / Names of Collaborators in Other Institutes Than Hub and Spoke Institutes
ARIM実施機関支援担当者 / Names of Collaborators in The Hub and Spoke Institutes

KIM CHAERIN

利用形態 / Support Type

(主 / Main)機器利用/Equipment Utilization(副 / Sub),技術補助/Technical Assistance


利用した主な設備 / Equipment Used in This Project

KU-518: CCDマルチICP発光分光分析装置


報告書データ / Report

概要(目的・用途・実施内容)/ Abstract (Aim, Use Applications and Contents)

本研究では、ナノメディシンが細胞内の鉄含有量に与える影響を評価することを目的としています。がん微小環境の改善を目指し、細胞内外の鉄を制御可能なナノメディシンの開発を進めています。その作用メカニズムを明らかにするため、ナノメディシン処理後の細胞および組織における鉄の定量分析を行います。本課題では、ICP-MSを用いて、細胞培養液および動物組織由来の試料中に含まれる鉄濃度(ng/ml または µg/ml)を測定します。試料は99%硝酸で灰化処理を行った後、10%硝酸で希釈し、全てろ過済みでICP-MS測定に適した状態となっています。また、濃度決定のために、濃度勾配を持つ標準試料を用いて標準曲線を作成します。

実験 / Experimental

Biological samples, including animal tissues, were accurately weighed and placed in clean polyethylene vials. To each sample, 0–40 µL of Milli-Q water was added to form a slurry or solution. The mixture was gently vortexed or shaken to ensure uniform dispersion or dissolution. For soft tissues such as liver, complete dissolution was observed without the need for additional digestion steps. Prepared samples were introduced into an inductively coupled plasma optical emission spectrometer (ICP-OES, SPECTROARCOS, Hitachi]) for elemental analysis. The instrument was calibrated using standard solutions of known iron concentrations. Certified reference materials (CRMs), including standard liver samples, were used to validate the method. Measurements were repeated in triplicate to assess precision and reproducibility

結果と考察 / Results and Discussion

A simple and efficient method for the preparation of biological samples for analysis by inductively coupled plasma optical emission spectrometry (ICP-OES) is proposed. The procedure involves forming a solution or slurry by mixing a small aliquot of sample with 0–40 µL of Milli-Q water. This approach enabled complete dissolution of soft animal tissues such as liver without the need for acid digestion. The method was validated using certified reference materials, and iron (Fe) concentrations in standard liver samples were successfully determined with reasonable precision and reproducibility.

図・表・数式 / Figures, Tables and Equations
その他・特記事項(参考文献・謝辞等) / Remarks(References and Acknowledgements)


成果発表・成果利用 / Publication and Patents

論文・プロシーディング(DOIのあるもの) / DOI (Publication and Proceedings)
口頭発表、ポスター発表および、その他の論文 / Oral Presentations etc.
特許 / Patents

特許出願件数 / Number of Patent Applications:0件
特許登録件数 / Number of Registered Patents:0件

印刷する
PAGE TOP